The door functions shall be controlled by a five position membrane switch. The following modes shall be selectable:
Auto: For normal use. The door operates in a fully automatic mode for two-way traffic.
Half Open/Three Quarter Open
For adverse climate conditions, door operates as in auto mode but only opens halfway.
Open: The door will remain fully open.
Lock: The door closes and the motor lock engages. It ignores all inputs except emergency exit, security and fire open signals.
Exit: The door closes and the motor lock engages. The door will open for traffic leaving the building only.
All of the following functions shall be independently adjustable:
FAILSAFE AND BATTERY
To be a fully monitored UPS system monitoring both battery and door operation. In case of power failure in auto mode the battery shall continue to provide full operation of the door for 200 complete open and close cycles. When the battery is too low to run the operator the doors will failsafe open. In case if power failure in lock mode the battery shall retain full locking for 8 hours.
The operator can be fitted with an Ultra-ID Security IO Panel. This interface will allow easy integration with any building management systems. Wiring to building management system by others.
The interface shall have clean contact relay outputs for the following functions. These outputs are selectable by jumper to be either normally open or normally closed. Activation of the relay is accompanies by an LED indication for easy fault diagnosis.
Power Supply
Motor
Power Consumption
Operation
Drive System
Maximum Weight
Door Leaf
Maximum Opening
Speed Per Leaf
230 Volt AC 50Hz
40 Vol DC Permanent Magnet
300 watts max
Continuous Rated
Toothed Timing Belt
Single 100kg
Bi-parting 90kg each
Single 500mm/sec
Bi-parting 1000mm/sec
Maximum Closing force limited to
Minimum Operator Length
Maximum Operator Length
Hold Open Time
Failsafe
Early Morning Entry Feature
Battery Level Indicator
130N
Single 1700mm
Bi-parting 2100mm
Single 4000mm
Bi-parting 6000mm
0-60 seconds
Standard
Standard
Standard
Power Supply
Motor
Power Consumption
Operation
Drive System
Maximum Weight
Door Leaf
Maximum Opening
Speed Per Leaf
Maximum Closing force limited to
Minimum Operator
Length
Maximum Operator
Length
Hold Open Time
Failsafe
Early Morning Entry Feature
Battery Level Indicator
230 Volt AC 50Hz
40 Vol DC Permanent Magnet
300 watts max
Continuous Rated
Toothed Timing Belt
Single 100 kg
Bi-parting 90kg each
Single 500mm/sec
Bi-parting 1000mm/sec
130N
Single 1700mm
Bi-parting 2100mm
Single 4000mm
Bi-parting 6000mm
0-60 seconds
Standard
Standard
Standard
We supply and service commercial automatic sliding door equipment, automatic gates and architectural hardware, satisfying customers with quality products at a competitive price.